NDT 705
The NDT 705 is an inexpensive, easy to use thickness gauge for spot
checking corroded or eroded metals. It has been designed for the inspector who
occasionally needs an accurate instrumentand is not built to take the daily wear and tear
of the full-time NDE technician.
Principle - Ultrasonic Pulse-echo with dual element transducer
Measurement Range - 0.04 to 20.00 inches (1.0 to 500mm) in steel
depending on transducer, material and surface condition
Transducer - Standard ¼ dia. x 5 MHz with 3 foot long integral cable
Others
available for special applications
Calibration - Single point automatic calibration
Can also calibrate to a know material velocity
Frequency - Selectable 2 or 5 MHz
Automatic V-Path Correction
Selectable inch or metric units of display
Resolution - From 0.04 to 4.00 = 0.001 More than 4.00
= 0.01
1
to 100mm = 0.025mm More than
100mm = 0.1mm
Gain - Adjustable for different transducers
Alarm - Programmable lower limit activated luminous LED
Display - 0.56 high 4 digit LCD with switchable backlight
Keypad - Sealed, dustproof and watertight membrane keypad
Automatic Turn OFF after 3 minutes of no use or manually by keypad
Powered by two 1.5V size AA alkaline batteries
Operating Time - Up to 100 hours using alkaline batteries without
backlight
High impact molded ABS plastic housing
Size - 5H x 2.8W x 1.4 (125 x 70 x 35mm)
Weight - 12 oz. including batteries
Standard Kit Includes the Gauge with alkaline batteries,
1/4" element diameter 5.0 MHz Transducer with integral cable, 4 oz. bottle of
ultrasonic gel Couplant, Operation Manual, Quick Guide Card and foam-lined aluminum Carry
Case
Click for NDT-705 .pdf document
Back to Top
NDT 710

The
NDT 710 is a small hand held thickness gauge that is very easy to use for spot
measurements of corroded or eroded metals, plastics and many other materials. Gauge
memory retains last calibration and measurement reading even after the unit has been
turned off.
Sound Velocity Range: 0.0197 to 0.3930 in/ms (500 to 10,000 m/s)
Size: 1.4" H. x 3.1" W. x 5.7" L (35mm x 79mm x 145mm)
Temperature Range: + 10 to 120 F (-10 to 50 C)
High impact molded ABS plastic housing
Weight: 11 oz. with batteries (309 grams)
Powered by a single 9 volt alkaline battery.
Click for NDT-710 .pdf document
NDT
715
The NDT 715 offers the same specifications as our field
proven 710
gauge. It is a small, hand held thickness gauge, only 2.5"W x
4.75"H x 1.25"D and weighing only 10 oz. It is designed to make reliable
spot check measurements an has a SCAN MODE that will capture and display the thinnest
measurement taken during a strip scan along a length of material. Housed in a
extruded, anodized aluminum housing with nickel plated aluminum end caps and a weather
resistant keypad the gauge is a bit more rugged than the 710 making it suitable for your
toughest working condition. The 715 is also more resistant to potential interference
from RFI fields than the 710.
Click for NDT-715 .pdf document
Sound Velocity Range: 0.0492 to 0.3930 in/ms (1250 to 10,000 m/s)
Size: 1.7" H. x 2.4" W. x 4.75" L (32mm x 62mm x 120mm)
Temperature Range: - 20 to 120 F (-20 to 50 C)
Weight: 10 oz. with batteries (284 grams)
Powered by two AA 1.5V alkaline batteries
SPECIFICATIONS
Common to both the NDT 710 and NDT 715 Gauges
Principle:
Ultrasonic Pulse-echo with dual element transducer
Range: 0.030 (0.75mm) to 19.99 (199.99mm max.) depending upon transducer used and material
Resolution: 0.001 (0.01mm)
Automatic linearity adjustment
Automatic Zero adjustment with transducer on calibration block
Automatic Shut-Off 2 minutes after last reading or last key press
Built in Probe Zero calibration block
Easy to read back lighted Liquid Crystal Display (LCD) with Coupling Indicator
Instant switching between English or Metric measurement
Up to 75 hours continuous operation using alkaline batteries
Low Battery Indicator
Standard Kit Includes the NDT-710 or NDT-715 Gauge with alkaline batteries,
1/4" element diameter x 5.0 MHz Transducer on 4 foot long integral cable, 4 oz.
bottle of ultrasonic gel Couplant, Operation Manual and padded nylon Carry Bag with
shoulder strap
Back to Top
NDT 815 MVX A
very versatile digital thickness gauge with thickness, A-Scan and B-Scan display and Data
Logging Capability.
Click for NDT-815 .pdf
document

The NDT 815 is equipped with multiple
viewing options to provide users with a complete set of inspection tools: (RF waveform,
+/- Rectified waveform, Time based B-Scan, and Large Digits).
The
adjustable square wave pulser provides the flexibility necessary for both high resolution
and penetration requirements.
The A-Scan rectified mode is commonly used for detecting flaws/pits in
pulse-echo mode and measuring thru-paint and coatings in echo-echo mode.
The time-based B-Scan feature of the NDT 815 displays a cross section
of the test material. It is commonly used to display the profile of the bottom surface of
the test material.
Built-in AGC gain control for thru-paint measurements in multi-mode
operation.
The variety of calibration options is just one more example of NDT
815s overall versatility.
The NDT 815 has the ability to store 64 custom user-defined setups.
All factory setups can be selected, edited and saved to any setup location.
The NDT
815 is equipped with an alpha-numeric data logger to provide increased versatility for
those custom reporting needs.
The built-in transducer types offer increased linearity between
transducers.
The high speed scan feature speeds up the inspection process by making
32 measurements per second. Remove transducer from the test material and display the
minimum measurement scanned.
Use the visual alarm to set hi and lo limits for applications
requiring specific tolerances. If the actual thickness value is above or below the limits,
a red light is illuminated.
Use the find feature to locate the detection point, while
automatically adjusting the display to bring the signal into view.
Comes complete with Windows® based software and interface cable for
transferring data to & from a PC.
2 year limited warranty
SPECIFICATIONS
Physical
Weight: 13.5 ounces (with batteries).
Size: 2.5 W x 6.5 H x 1.24 D inches (63.5 W x 165 H x 31.5 D mm).
Operating Temperature: -14° to 140°F (-10° to 60°C).
Keyboard: Membrane switch with twelve tactile keys.
Case: Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed).
Data Output: Bi-directional RS232 serial port. Windows® PC interface software.
Display: 1/8 in. VGA grayscale display (240 x 160 pixels).
Viewable area 2.4 x 1.8 in. (62 x 45.7mm).
EL backlit (on/off/auto).
Ultrasonic
Measurement Modes: Pulse-Echo (flaws, pits) and Echo-Echo (thru-paint)
Pulser: Square wave pulser with adjustable pulse width (spike, thin, wide).
Receiver: Manual or AGC gain control with 40dB range, depending on mode selected.
Timing: 20 MHz with ultra low power 8 bit digitizer.
Power Source
Three 1.5V alkaline or 1.2V NiCad AA cells. Typically operates for 150 hours on alkaline
and 100 hours on NiCad (charger not included.)
Auto power off if idle 5 min. Battery status icon.
Measuring
Range in Pulse-Echo Mode: (Pit&Flaw Detection) measures from 0.025 to 9.999
inches
(0.63 to 254 millimeters).
Range in Echo-Echo Mode: (Thru Paint & Coatings) measures from 0.10 to 4.00
inches
(2.54 to 102 millimeters).
Range will vary +/- depending on the thickness of coating.
Resolution: +/- .001 inches (0.01 mm)
Velocity Range: .0492 to .3936 in./ms 1250 to 9999 meters/sec
Calibration: Single and Two point calibration option, or selection of basic material
types.
Units: English & Metric
Display
Display Views:
A-Scan Rectified +/- (flaw view) RF (full waveform view)
B-Scan Cross sectional view. Display speed of 15 secs per screen.
Large Digits Standard thickness view. Digit Height: 0.400 in (10mm).
Scan Bar 6 readings per second. Viewable in B-Scan and Large Digit views.
Repeatability Bar Graph Bar graph indicates stability of reading
Data Logger: 12,000 pages of memory (alpha numeric storage).
Page contents: 1 reading and 1 waveform per page.
OBSTRUCT to indicate inaccessible locations.
Memory: 16 megabit non-volatile ram.
Transducer
Transducer Types: Dual Element (1 to 10 MHz).
Locking quick disconnect 00 LEMO connectors. Standard 4 foot cable.
Custom transducers and cable lengths available for special applications.
Features
Setups: 64 custom user-definable setups. Factory setups can also be edited by
the user.
Gates: Single gate in pulse-echo mode, or single gate with holdoff in echo-echo
mode. Adjustable threshold. Selectable Transducers: Selectable transducer types with
built-in
dual path error correction for improved linearity.
Alarm Mode: Set HI and LO tolerances with audible beeper and visual LEDs.
Fast-Scan Mode: Takes 32 readings per second and displays the minimum reading found
when the transducer is removed.
Certification
Factory calibration: traceable to national standards.
Standard Kit Contents the NDT 815 instrument, 1/4" diameter x 5.0 MHz dual element
transducer on 4 foot long cable, (3) size AA Alkaline Batteries, 4 oz. plastic bottle of
Ultrasonic Couplant, Operation Manual, Serial Interface Cable, Data Management Software,
Hard-shell Carrying Case and Certificate of Calibration.
Back to Top |
MMX-6 A dual element gauge with both pulse-echo and multi-echo
(thru paint) measurement capability.
MMX-6DL includes a 1000 reading data logger
Click for MMX-6/6DL .pdc document
SPECIFICATIONS
Physical
Weight: 10 ounces (with batteries).
Size: 2.5W x 4.5H x 1.24D inches (63.5W x 114.3H x 31.5D mm).
Operating Temp: 20° to 120°F (-30° to 50°C).
Case: Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed).
Keypad: Sealed membrane that is resistant to both water and petroleum products.
Nine tactile-feedback keys.
Transducer: Dual-element (transmit and receive). 1 to 10 MHz frequency
Special high-damped transducers available for Through Paint and Coating measurements
Locking quick disconnect LEMO connectors on 4 foot cable.
Custom transducers available for special applications.
Measuring
Resolution: 0.001 inch (0.01 millimeter)
Velocity Range: 0.0492 to .3937 in/µs 1250 to 10,000 meters/second)
Range: Pulse-Echo Mode (Pit & Flaw Detection) measures from 0.025 to 19.999 inches
(0.63 to 500 millimeters).
Echo-Echo Mode (Through Paint & Coatings) measures from 0.1 to 1 Inch (2.54 to 25.4
millimeters).
Switchable to either English or Metric units.
Built in Stainless steel reference disk for probe zeroing.
Measurement Rate: Four readings per second for single point measurements or 16 per second
in Scan Mode-captures the minimum thickness. Calibration: Single and two point calibration
option included.
Features
Multi-Mode:Toggle between Pit & Flaw Detection (Pulse Echo Mode), or Through Paint
& Coatings (Echo-Echo Mode) with a single button.
Alarm Mode: Enter a minimum acceptable thickness value. If measurement falls below minimum
a red LED will illuminate and beeper will sound.
If measurement is above minimum value, green LED will illuminate.
Data Output: RS232 output sends data to a serial printer, a computer or other external
storage device.

Power Source
Two 1.5V alkaline or 1.2V NiCad AA cells.
Typical operation 200 hours on alkaline; 130 hours on NiCad.
Display flashes when battery is low. Unit turns off automatically when battery is too low
to operate reliably.
Display
Multi-function 4.5 digit LCD display with 0.500 inch high numerals, backlit for use in
poor light conditions.
Backlight is selectable on/off/auto (illuminates only when taking a measurement).
Measurements displayed in inches, inches/microsecond, millimeters and meters/second.
Bar graph indicates stability of reading.
Internal Data Logger (MMX-6DL only)
Automatic numeric Data Logging system 1 to 1000 readings.
OBST indicates no reading.
Certification
Factory calibration traceable to national standards.
5 year limited Warranty
Standard Kit includes MMX-6 Gauge, 5 MHz dual transducer & cable, 4 oz. bottle of
couplant, operation manual and carry case. PC interface cable and software included with
the DL model.
Back to Top
MMX-7 A dual element multi-echo (thru paint) gauge with large digit numeric and
B-Scan displays and Data Logger
Click for MMX-7
.pdf document
Pulse-echo Mode for flaw and pit measurement and Multi-Mode
(Echo-Echo mode) to measure through and eliminate paint and coatings. Built-in
automatic gain control.
Time based B-Scan feature displays a cross section of the opposite surface
allowing inspectors to the contour of the back surface.
Selectable low, medium, and high multiple gain settings offer the inspector
the additional punch power for materials that are hard to penetrate.
Store up to 64 custom setups. Factory setups are included for common
applications.
Alpha-numeric data logger to provides increased versatility for custom
reporting needs and stores up to 12,000 measurements.
Built-in transducer types offer increased linearity between transducer
frequencies and diameters.
High speed scan feature provides a better representation during the scanning
process, by making 32 measurements per second. Remove the transducer from the test
material to display the thinnest measurement found during strip scan.
Use the visual alarm to set Hi and Lo limits to alert inspector when the
measurements are out of tolerance.
Windows PC software to transfer data to and from a PC, view B-Scans and general
measurements, set break-points, view statistics, and export files into excel.
2 year limited warranty
Specifications:
Physical
Weight: 13.5 ounces (with batteries).
Size: 2.5 W x 6.5 H x 1.24 D inches (63.5 W x 165 H x 31.5 D mm).
Operating Temperature: -14° to 140°F (-10° to 60°C).
Keyboard: Membrane switch with twelve tactile keys.
Case: Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed).
Data Output: Bi-directional RS232 serial port. Windows® PC interface software.
Display: 1/8 in. VGA grayscale display (240 x 160 pixels). Viewable area 2.4 x 1.8 in. (62
x 45.7mm).
EL backlit (on/off/auto).
Ultrasonic
Measurement Modes: Pulse-Echo (flaws, pits) and Echo-Echo (thru-paint)
Square wave pulser.
Receiver: Selectable low, medium or high gain in pulse-echo mode. AGC gain
control in ech0-echo mode.
Timing: 20 MHz with ultra low power 8 bit digitizer.
Power
Source
Three 1.5V alkaline or 1.2V NiCad AA cells. Typically operates for 150 hours on alkaline
and 100 hours on NiCad (charger not included.)
Auto power off if idle 5 min. Battery status icon.
Measuring
Pulse-Echo Mode Range: (Pit&Flaw Detection) measures from 0.025
to 9.999 inches
(0.63 to 254
millimeters).
Echo-Echo Mode Range: (Thru Paint & Coatings) measures from 0.050 to 4.0 inches
(1.27 to 102 millimeters).
Range will vary +/- depending on the thickness of coating.
Resolution: +/- .001 inches (0.01 mm)
Velocity Range: .0492 to .3936 in/ms 1250 to 9999 meters/sec
Calibration: Single and Two point calibration option, or selection of basic material
types.
Units: English & Metric
Display
Display Views:
Large Digits is Standard thickness view. Digit Height: 0.400 in (10mm).
B-Scan Cross sectional view. Display speed of 15 secs per screen.
Scan Bar Thickness 6 readings per second. Viewable in B-Scan and Large Digit views.
Repeatability Bar Graph Bar graph indicates stability of reading
Data Logger (Internal): 12000 and B-Scans (alpha numeric storage).
Memory: 16 megabit non-volatile ram.
Transducer
Transducer Types: Dual Element (1 to 10 MHz).
Locking quick disconnect 00 LEMO connectors. Standard 4 foot cable.
Custom transducers and cable lengths available for special applications.
Features
64 custom user-definable setups. Factory setups can also be edited by the user.
Selectable transducer types with built-in dual path error correction for improved
linearity.
Alarm Mode: Set HI and LO tolerances with audible beeper and visual LEDs.
Fast-Scan Mode takes 32 readings per second and displays the minimum reading found when
the transducer is
removed. Display continuously updates while scanning.
Certification
Factory calibration: traceable to national standards.
Standard Kit Contents: MMX-7 instrument, 1/4" diameter x 5.0 MHz dual element
transducer on 4 foot long cable, (3) size AA Alkaline Batteries, 4 oz. plastic bottle of
Ultrasonic Couplant, Operation Manual, Serial Interface Cable, Data Management Software,
Hard-shell Carrying Case and Certificate of Calibration.
Back to Top
CMX A versatile ultrasonic thickness gauge that combines the ability to
measure wall thickness with or without coatings and simultaneously measure the coating
itself. Time-based B-scan and large data storage capacity compliment the advanced
features of this brand-new gauge. Available in three models. Standard (CMX),
with data logging (CMXDL) and with data lgging, A and B-Scan display and three independent
gates (CMXDL+)
Click
for CMX Series .pdf document

Measurement Modes:
* Coating on: Pulse-Echo Coating (PECT)
* Coating off: Pulse-Echo (P-E)
* Temp Comp: Pulse-Echo Temperature compensated (PETP)
* Thru-Paint: Echo-Echo (E-E)
* Coating Only: Coating (CT)
Features:
* Auto Probe Recognition
* Auto Probe Zero
* Auto Temperature Compensation
* Adjustable Gain - (v-low, low, med, high, v-high)
* Time based B-Scan (cross section view)
* High Speed Scan
* High/Low Alarm - dynamic update of both
* Differential Mode
* Transducer Linearity Selector
* Material Chart
* 64 Custom Setup Capability
* Massive Data Storage (CMXDL & CMXDL+)
(Graphics ON) 16,000+ readings, B-Scans, & gauge settings for every stored reading
(Graphics OFF) 210,000+ readings - including material, coating, min & max for all
readings

CMXDL+
ELECTRONIC PLATFORM:
Powered by a 100MHz DSP platform using FPGA technology.
Two Channels - Dual pulsers and receivers.
Up to 140Hz pulse repetition rate.
Display update rate of 25 times per second.
Adjustable gain settings - vlow, low, med, hi, vhi.
Automatic gain control (AGC).
Time corrected gain (TCG).
Massive data storage (32 Megabit of non-volatile RAM).
FEATURES:
Viewing Options:
A-Scan (RF waveform, +/- Rectified waveform), Time-Based B-Scan,
and Large Digits.
Measurement modes:
Pulse-Echo, Pulse-Echo w/Coating, Pulse-Echo w/Temperature
Compensation,
Echo-Echo, Echo-Echo Verify, & Coating Only.
Automatic: probe zero, probe recognition, and temperature compensation.
Stores up to 64 custom setups for specific applications.
High Speed Scan of up to 50 readings per second.
Audible/visual alarm with hi and lo limit settings.
Built-in differential mode for QC inspections.
Time based B-Scan feature for cross section material scans.
Attenuator: 20db cut/boost.
pulser: 50 volt cut/boost (100 - 200 volts).
Data storage formats: Alpha numeric grid and sequential w/auto identifier.
Windows PC software included.
2 year limited warranty.
Certification: Factory calibration: traceable to national standards.
Standard Kit Contents the CVX instrument, transducer on 4 foot long cable, (3) size AA
Alkaline Batteries, 4 oz. plastic bottle of Ultrasonic Couplant, Operation Manual, Serial
Interface Cable, Data Management Software, Hard-shell Carrying Case and Certificate of
Calibration.
Back to Top
|